Répertoire de l'Université Alfonso X el Sabio

Comparative Study of the SEM Evaluation, EDX Assessment, Morphometric Analysis, and Cyclic Fatigue Resistance of Three Novel Brands of NiTi Alloy Endodontic Files

Afficher la notice abrégée

APA

Faus Matoses, Vicente & Pérez García, Raúl & Faus Llácer, Vicente & Faus Matoses, Ignacio & Alonso Ezpeleta, Óscar & Albaladejo Martínez, Alberto & Zubizarreta Macho, Álvaro .Comparative Study of the SEM Evaluation, EDX Assessment, Morphometric Analysis, and Cyclic Fatigue Resistance of Three Novel Brands of NiTi Alloy Endodontic Files.

ISO 690

Faus Matoses, Vicente & Pérez García, Raúl & Faus Llácer, Vicente & Faus Matoses, Ignacio & Alonso Ezpeleta, Óscar & Albaladejo Martínez, Alberto & Zubizarreta Macho, Álvaro. Comparative Study of the SEM Evaluation, EDX Assessment, Morphometric Analysis, and Cyclic Fatigue Resistance of Three Novel Brands of NiTi Alloy Endodontic Files.

https://hdl.handle.net/20.500.12080/29558
dc.contributor.author Faus Matoses, Vicente
dc.contributor.author Pérez García, Raúl
dc.contributor.author Faus Llácer, Vicente
dc.contributor.author Faus Matoses, Ignacio
dc.contributor.author Alonso Ezpeleta, Óscar
dc.contributor.author Albaladejo Martínez, Alberto
dc.contributor.author Zubizarreta Macho, Álvaro
dc.date.accessioned 2022-04-25T07:25:17Z
dc.date.available 2022-04-25T07:25:17Z
dc.date.created 2022-04-06
dc.identifier.uri https://hdl.handle.net/20.500.12080/29558
dc.description.abstract : In this study, we compare and analyze the scanning electron microscopy (SEM), energydispersive X-ray spectroscopy (EDX), morphometry and cyclic fatigue resistance of Endogal, PathMax, and Smarttrack novel brands of nickel¿titanium (NiTi) alloy endodontic files. Material and Methods: Thirty sterile NiTi endodontic rotary files were randomly selected and assigned to one of the following study groups: A: 25.08 F2 Endogal (EDG) (n = 10); B: 25.08 F2 Path Max Pro (PMP) (n = 10); and C: 25.06 Smarttrack (ST) (n = 10). Dynamic cyclic fatigue tests were conducted using a cyclic fatigue device in stainless steel artificial root canal systems with an apical diameter of 250 µm, curvature angle of 60¿ , radius of curvature of 3 mm, and taper of 6%. Additionally, we analyzed the NiTi endodontic rotary files using EDX, SEM, and morphometry after micro-CT scanning. The results were analyzed using Weibull statistical analysis and ANOVA testing. Results: SEM, EDX, and morphometric analyses showed differences between the three novel brands of NiTi endodontic rotary files. Moreover, statistically significant differences were observed between the number of cycles to failure and time to failure of the three novel brands of NiTi endodontic rotary files (p < 0.001). Conclusions: Smarttrack NiTi alloy endodontic reciprocating files display greater resistance to cyclic fatigue than Endogal and Path Max Pro NiTi alloy endodontic rotary files, due to the reciprocating movement and metallurgical composition. Keywords: cyclic fatigue; endodontics; energy-dispersive X-ray; scanning electron microscopy; morphometry; reciprocating; continuous rotation; NiTi es_ES
dc.format application/pdf es_ES
dc.language eng es_ES
dc.rights CC-BY es_ES
dc.rights.uri http://creativecommons.org/licenses/by/4.0/deed.es es_ES
dc.title Comparative Study of the SEM Evaluation, EDX Assessment, Morphometric Analysis, and Cyclic Fatigue Resistance of Three Novel Brands of NiTi Alloy Endodontic Files es_ES
dc.type info:eu-repo/semantics/article es_ES
dc.rights.accessrights info:eu-repo/semantics/openAccess es_ES
dc.identifier.location N/A es_ES


Fichier(s) constituant ce document

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

CC-BY Excepté là où spécifié autrement, la license de ce document est décrite en tant que CC-BY

Chercher dans le dépôt


Parcourir

Mon compte

Social Media