Mostra i principali dati dell'item
dc.contributor.author | Faus Matoses, Vicente | |
dc.contributor.author | Faus Llácer, Vicente | |
dc.contributor.author | Aldeguer Muñoz, Álvaro | |
dc.contributor.author | Alonso Pérez-Barquero, Jorge | |
dc.contributor.author | Faus Matoses, Ignacio | |
dc.contributor.author | Ruiz Sánchez, Celia | |
dc.contributor.author | Zubizarreta Macho, Álvaro | |
dc.date.accessioned | 2022-04-18T14:52:53Z | |
dc.date.available | 2022-04-18T14:52:53Z | |
dc.date.created | 2022-03-22 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12080/29540 | |
dc.description.abstract | Abstract: The present study seeks to describe a novel digital measurement technique for analyzing the wear volume of controlled memory (CM)-wire NiTi alloy endodontic reciprocating files after clinical use. Material and Methods: Ten CM-wire NiTi endodontic reciprocating files were randomly used in ten first upper molar teeth within four root canals. The CM-wire NiTi alloy endodontic reciprocating files were subjected to preoperative and postoperative micro-computed tomography (micro-CT) scans to obtain accurate digital imaging and communication on medicine (DICOM) digital files, which were segmented using intensity-based thresholding and an exclusive OR (XOR) logical operation (Boolean algebra logical operator) to obtain a mask of the location to localize and quantify the wear volume of the CM-wire NiTi alloy endodontic reciprocating files. Gage repeatability and reproducibility statistical analysis was applied to assess the reproducibility and repeatability of this measurement technique. Results: The analysis showed a repeatability and reproducibility of 0.00% for the digital measurement technique used to analyze the wear volume of CM-wire NiTi alloy endodontic reciprocating files after clinical use. Wear was mostly identified at the tip and cutting edges of the CM-wire NiTi alloy endodontic reciprocating files. Conclusions: This novel digital measurement technique is a repeatable, reproducible, and accurate method of quantifying the wear volume of CM-wire NiTi alloy endodontic reciprocating files after clinical use. Keywords: endodontics; cyclic fatigue; wear; NiTi; reciprocating movement; micro-computed tomography | es_ES |
dc.format | application/pdf | es_ES |
dc.language | eng | es_ES |
dc.rights | CC-BY | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/deed.es | es_ES |
dc.title | A Novel Digital Technique to Analyze the Wear of CM-Wire NiTi Alloy Endodontic Reciprocating Files: An In Vitro Study | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | es_ES |
dc.identifier.location | N/A | es_ES |