Répertoire de l'Université Alfonso X el Sabio

Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study

Afficher la notice abrégée

APA

Zubizarreta Macho, Álvaro & Triduo, Martina & Pérez Barquero, Jorge Alonso & Guinot Barona, Clara & Albaladejo Martínez, Alberto .Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study.

ISO 690

Zubizarreta Macho, Álvaro & Triduo, Martina & Pérez Barquero, Jorge Alonso & Guinot Barona, Clara & Albaladejo Martínez, Alberto. Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study.

https://hdl.handle.net/20.500.12080/24011
dc.contributor.author Zubizarreta Macho, Álvaro
dc.contributor.author Triduo, Martina
dc.contributor.author Pérez Barquero, Jorge Alonso
dc.contributor.author Guinot Barona, Clara
dc.contributor.author Albaladejo Martínez, Alberto
dc.date.accessioned 2021-02-09T16:50:50Z
dc.date.available 2021-02-09T16:50:50Z
dc.date.created 2020-04
dc.identifier.uri https://hdl.handle.net/20.500.12080/24011
dc.description.abstract The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomography. The standard tessellation language digital files were aligned, segmented, and re-aligned using geomorphometric software. The digital measurement technique accuracy, repeatability, and reproducibility were analyzed using Gage R&R statistical analysis. The variability attributable to the area and volume measurement techniques of the total variability of the samples was 0.70% and 0.11% for repeatability, respectively, and 0.79% and 0.01% for reproducibility, respectively. The re-alignment procedure is a repeatable, reproducible, and accurate technique that can be used to measure the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere the fixed multibracket appliance. es_ES
dc.format application/pdf es_ES
dc.language eng es_ES
dc.rights CC-BY es_ES
dc.rights.uri http://creativecommons.org/licenses/by/4.0/deed.es es_ES
dc.title Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study es_ES
dc.type info:eu-repo/semantics/article es_ES
dc.rights.accessrights info:eu-repo/semantics/openAccess es_ES
dc.identifier.location N/A es_ES


Fichier(s) constituant ce document

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

CC-BY Excepté là où spécifié autrement, la license de ce document est décrite en tant que CC-BY

Chercher dans le dépôt


Parcourir

Mon compte

Social Media