Mostrar el registro sencillo del ítem
dc.contributor.author | O¿Connor Esteban, Miriam | |
dc.contributor.author | Riad Deglow, Elena | |
dc.contributor.author | Zubizarreta Macho, Álvaro | |
dc.contributor.author | Hernández Montero, Sofía | |
dc.date.accessioned | 2021-02-09T16:43:39Z | |
dc.date.available | 2021-02-09T16:43:39Z | |
dc.date.created | 2019-12 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12080/24009 | |
dc.description.abstract | The purpose of this study was to analyze the influence of the digital mock-up and operator experience on the dental implant planning position. A total of 200 dental implants were planned, which were distributed into two study groups: A. dental implant planning by dental surgeons with 5¿10 years of experience (n = 80); and B. dental implant planning by dental surgery students without experience (n = 120). Operators were required to plan eight dental implants in the same maxillary edentulous case uploaded in 3D implant-planning software, before and after using the digital mock-up. Deviations between the dental implant planning positions before and after using the digital mock-up were analyzed at platform, apical and angular levels, and were analyzed using a 3D implant-planning software using Student¿s t test. The paired t-test revealed statistically significant di erences between the deviation levels of participants with 5¿10 years¿ experience and no experience at the platform, apical and angular levels. Digital mock-ups allow for more accurate dental implant planning regardless of the experience of the operator. Nevertheless, they are more useful for operators without dental surgery experience. | es_ES |
dc.format | application/pdf | es_ES |
dc.language | eng | es_ES |
dc.rights | CC-BY | es_ES |
dc.rights.uri | N/A | es_ES |
dc.title | Influence of the Digital Mock-Up and Experience on the Ability to Determine the Prosthetically Correct Dental Implant Position during Digital Planning: An In Vitro Study | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | es_ES |
dc.identifier.location | N/A | es_ES |