Archivio dell'Università Alfonso X El Sabio

Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files

Mostra i principali dati dell'item

APA

Zubizarreta Macho, Álvaro & Mena Álvarez, Jesús & Albaladejo Martínez, Alberto & Segura Egea, Juan José & Caviedes Brucheli, Javier & Agustín Panadero, Rubén & López Píriz, Roberto & Alonso Ezpeleta, Óscar .Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files.

ISO 690

Zubizarreta Macho, Álvaro & Mena Álvarez, Jesús & Albaladejo Martínez, Alberto & Segura Egea, Juan José & Caviedes Brucheli, Javier & Agustín Panadero, Rubén & López Píriz, Roberto & Alonso Ezpeleta, Óscar. Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files.

https://hdl.handle.net/20.500.12080/24008
dc.contributor.author Zubizarreta Macho, Álvaro
dc.contributor.author Mena Álvarez, Jesús
dc.contributor.author Albaladejo Martínez, Alberto
dc.contributor.author Segura Egea, Juan José
dc.contributor.author Caviedes Brucheli, Javier
dc.contributor.author Agustín Panadero, Rubén
dc.contributor.author López Píriz, Roberto
dc.contributor.author Alonso Ezpeleta, Óscar
dc.date.accessioned 2021-02-09T16:41:01Z
dc.date.available 2021-02-09T16:41:01Z
dc.date.created 2019-12
dc.identifier.uri https://hdl.handle.net/20.500.12080/24008
dc.description.tableofcontents Purpose: To analyze the influence of the pecking motion frequency on the cyclic fatigue resistance of endodontic rotary files. Material and Methods: Sixty PlexV 25.06 endodontic rotary files were selected and distributed into three groups: 30 movements/min (n = 20), 60 movements/min (n = 20), and 120 movements/min (n = 20). A dynamic cyclic fatigue device was designed using Computer Aided Design/ Computer Aided Engineering (CAD/CAE) technology and manufactured by 3D impressions to simulate the pecking motion performed by an operator. Failures of the endodontic rotary files were detected by a Light-Emitting Diode (LED)/Light-Dependent Resistor (LDR) system controlled by an Arduino-Driver complex and management software. Endodontic rotary files were tested on an artificial root canal manufactured by wire electrical discharge machining (EDM), with similar dimensions to those of the instrument under examination. Endodontic rotary files were used following the manufacturer¿s recommendations. The results were analyzed by ANOVA and Weibull statistics. Results: All pairwise comparisons revealed statistically significant di erences in all three variables, except for the di erence in the number of cycles between the groups with 60 and 120 movements/min (p = 0.298). The scale distribution parameter ofWeibull statistics showed statistically significant di erences in all three variables, except for the di erences in the number of cycles between groups with 30 and 60 movements/min (p = 0.0722). No statistically significant di erences in the three variables were observed for the shape distribution parameter. Conclusion: A low frequency of pecking motion is recommended to reduce the risk of failure of endodontic rotary files associated with cyclic fatigue. es_ES
dc.format application/pdf es_ES
dc.language eng es_ES
dc.rights CC-BY es_ES
dc.rights.uri N/A es_ES
dc.title Influence of the Pecking Motion Frequency on the Cyclic Fatigue Resistance of Endodontic Rotary Files es_ES
dc.type info:eu-repo/semantics/article es_ES
dc.rights.accessrights info:eu-repo/semantics/openAccess es_ES
dc.identifier.location N/A es_ES


Files in questo item

Questo item appare nelle seguenti collezioni

Mostra i principali dati dell'item

Cerca in DSpace


Ricerca

My Account

Social Media